editorinchief@ijsreat.com +91 9840521421 Scholarly Open Access, Peer-reviewed, Refereed Journal e-ISSN 2583-1240 Since 2021
  1. Home
  2. Archives
  3. 2025
  4. Vol. 5 Issue 6
  5. Article
Original Article

Smart Bandage: wound classification and bandage recommendation using DL

  • Paper ID 259
  • Volume 5, Issue 6
  • Pages 141-143
  • Published Online: November-December 2025
  • 18 Views
Open Access Peer Reviewed Crossref DOI

Authors

  • Dr. C. S Pillai1
  • Neeraj S2
  • Nithin R Gowda3
  • Bhoomika R4
  • Shreya Sharad Tamse5

1 2 3 4 5 Department of Computer Science & Engineering, Rajarajeswari College of Engineering Bangalore, Karnataka, India.

Article Information

Published Online
November-December 2025
Pages
141-143
Article Type
Original Article
Check for updates
check update

Abstract

View PDF

This research shows a smart bandage with wireless features to monitor motion and temperature, while using a no-battery NFC chip. Rather than common parts, the sensors are built from a conducting polymer named PEDOT: PSS. A section contains micro-channels in flexible PDMS rubber, loaded with this fluid material to detect bending. If pulled only 10% longer, its electric resistance rises nearly x times more than usual. This results in a quick reaction - almost instant - so it picks up tiny shifts right away. Not only does it detect stretching, but also handles far more strain than human skin or the chest endures during breaths. Beyond testing stretch alone, researchers looked at bending too, spotting clear electrical signals with each degree change. What’s more, it showed close to 12,000% resistance rise per single percent stretched. On top of that, a temperature-sensitive resistor built on PVC saw its resistance fall by about 60% when warmed, responding sharply - nearly per degree Celsius. To test actual use, one sensor along with an NFC chip was stuck on bandages - making them act like wearable smart patches. They work without wires when near a phone, pulling data smoothly from up to 25 mm distance through an app that runs the system. We prove such a patch might support medical needs - tracking healing cuts or lung problems like asthma, also virus- related conditions such as COVID-19. Here, sensing motion via flexible trackers together with temperature tools on body-worn gear makes a big difference

APC from ₹1200 + 18% GST

Peer-reviewed open access₹1200 Indian (₹1400 with DOI)$80 USD internationalpaid after acceptance Peer-reviewed open access₹1200 Indian$80 USD international ₹1200 Indian · $80 intl

  • CrossRef DOI
  • ISSN 2583-1240
  • Open Access
  • Peer Reviewed
  • Plagiarism Checked
  • Google Scholar